EE9 Version History
9.6.0.466 (27 Jan 2012)
General Changes in EE
-
Revised claims in Linearity and Calibration Verification from "Accuracy was not verified"
to "Accuracy was not evaluated in this experiment". This change was also made for
Linearity and Reportable Range when they are unchecked in the Parameters for this module. (EEC472)
9.5.0.462 (14 Jul 2011)
General Changes in EE
-
RRE, Define Policies, Analyte Settings now displays the Proximity Limits columns when Simple Accuracy has Verify Reportable Range enabled in Modules and Options. (EEC405)
-
Target Ranges are now supplied from Policies in Simple Accuracy in Experiment, New With Policies and in Instrument Data Capture (EEC384)
-
Policies, Target Ranges now validates entered data as numbers; Renaming a SpecID
no longer causes an error (EEC396)
-
Warnings are now issued when a user attempts to create Linearity-type experiments
that lack kit or target range values even if you do not view the RRE grid. (EEC404)
-
Fixed an error when Custom Linking of MC experiments (EEC379)
9.4.0.457 (11 Apr 2011)
The
General Changes in EE:
- One may now perform a Selective Recalc for any Statistical Module,
allowing recalculations for
selected instruments or analytes. (EEC017)
- The Inventory screen accessed from File,Project Inventory and from the
File Manager cut off the
Status column. This has been fixed. (EEC214)
- Help was written for the Audit Viewer, AuditVue (EEC229)
- The software now warns the user if the end of the licensing period
is within 60 days, within 30
days, and every time the software is run within 15 days (EEC255)
- An error could appear when previewing report data, then deleting the
experiment, and then
attempting to paste it back into the module overview screen. This has
been fixed. (EEC256)
- LOB data has been added to PasteWithPoliciesList.XLS in the
Resources folder. (EEC262)
- HIS data has been added to PasteExptDetail.XLS in the Resources
folder. (EEC269)
- Downloading a new version now checks available disk space prior to
starting the download. An
informative message will be displayed if enough space does not exist.
(EEC288)
- A spelling error appeared on the window that shows when files are
restructured for upgrade.
This has been fixed. (EEC289)
- The "New Software Available" hint on the upper right part of the
main EE screen may now be
disabled by adding the file "NoNewRelMessage" in the main EE folder.
(EEC300)
- Data Exported from EE and then modified in Excel can now be Imported
back into EE. (EEC318)
AMC
- Percent Bias is now calculated and displayed on the AMC report output,
and on the Stats tab
of the experiment detail screen. (EEC320)
AON
- The AON Data Manager will now accept dates that are in yyyy-mm-dd
format. (EEC186)
CO
- If an experiment with insufficient data was imported into the
Carryover module, a vague warning
would appear in the activity log. This has been clarified to include the
words "insufficient
data". (EEC267)
ERI/ROC
- ERI/ROC produced an error when the Experiment, New or F3 Add options
were used. This has been fixed. (EEC290)
- There was a spelling error on the ROC Comparison, Detail screen.
This has been fixed. (EEC294)
- The ERI/ROC data definition box that appears when you choose to add
a new experiment using F3 Add or Experiment, New functions, showed
cut-off text. This has been fixed. (EEC312)
- There was a spelling error on the Datasheet Description box in
ERI/ROC (accessed from F2
Rename). This has been fixed. (EEC313)
- ERI/ROC can now acquire data from IM; ERI/ROC does not require the
presence of Policies in
order to acquire data from IM. Also see IM_ODBC in this document for new
ERI/ROC data
acquisition features.
HIST
- The user can now enter a cutoff percentile in the Parameters screen,
and the cutoff result
value is computed and displayed on the screen and in the report.
(EEC216)
INR
- GEO
- The ISI field on the parameters for INR-GEO experiments had a
descriptor added that states what
the allowed values are for the field. (EEC266)
IM_ODBC
- Rapid Results Entry, Connect to Instrument Manager how can access data
in the IM Archive
database. This is available on the main IM ODBC Connection screen from
the Connection menu.
(EEC202)
- Patient demographic data can now be accessed when acquiring data for
ERI/ROC experiments. The specific IM fields are defined in a new file in
the EE9 folder, called "ODBC_IM_ERI_Fields.txt". The most useful IM
fields are sex/gender and date of birth (from
which age is computed). (EEC307)
- Data acquired from IM is now saved in the
\EE9\DATA\STUDIES\project\RRE folder (where "project" is the name of
your project/study) in a file named "ss-IM_ODBC-nnn.TXT" (where "ss" is
an abbreviation for the Statistical Module, and "nnn" is an incrementing
number). (EEC151)
Simple
Accuracy
- When pasting data into the overview screen, only 7 of 11 levels were
accepted by EE. This has
been fixed. (EEC295)
Incident
Tracking
- The Enter/Edit button in Incident Tracking was split into two buttons
: Enter Incidents (for
adding new incidents to the database) and Edit Incidents (for modifying
existing incidents).
(EEC134)
- A new Copy Database option was added to the File menu of Incident
Tracking. Only the Setup
options will carry over to the new database (with the option to copy
user logins); existing
incidents will not be copied. (EEC135)
- Incident Tracking uses the institution information entered into EP
Evaluator (when the unlock
code is provided) on report headers and screens. (EEC137)
- In one case, the incident displayed when the Details button was
clicked from the Browse window
was not the one selected in the grid. This has been fixed. (EEC138)
- Close Incident and Re-Open Incident buttons were added to the
incident tracking form. The
'Re-Open Incident Reports' permission was added to security, and the
Administrators and
Investigators security groups initially have this permission. Closed
incidents are unable to be
edited and will need to be re-opened by a user with the appropriate
permissions. (EEC141)
- Users can now print a data entry form, as well as a list of fields
and valid field values, from
the Setup screen; this data can also be placed in the clipboard to allow
creation of custom
forms using Excel. Cosmetic problems with the printed report have also
been fixed.
(EEC140, EEC201)
- A Print Preview button was added to both the Enter and Edit
Incidents screens. (EEC194)
- Fields that are flagged as Investigator-Only in Setup are now
neither displayed nor editable in
the Incident Editor, in Browse, and in Breakdown. (EEC199)
- If Incident Tracking Setup fields were set to Show Investigator Only
= Yes and the logged in
user did not have the permission 'Edit Investigator Fields' in security,
the values would show
with asterisks in the Browse grid; they now show as blank fields.
(EEC328)
Inventory
(SIS)
- The 'Has Lots' column is now a sortable column in the grid on the
Items screen. (EEC3)
- The Transaction Viewer now shows the name of the user logged in
while making the change, and to which lot number (if applicable).
(EEC83)
-
Institution information entered into EP Evaluator (when the unlock code
is provided) is now
used on report headers and screens. (EEC137)
-
It is now possible to produce a QOH report using a subset of selected
items on the QOH screen.
Additionally, the option to print a QOH report is now available on the
Items screen (however,
it will show all records on this screen and not only-selected). (EEC154)
-
The text on the 'Stop Asking' checkbox when the user accesses the
'Select Database' window in
Inventory (SIS) was changed to 'Always use above database'. (EEC157)
- The copyright date was adjusted to 2011. (EEC158)
- Count Sheets are now correctly being created from the QOH screen.
Also, the ability to create
shopping lists and count sheets from the Items screen has been disabled.
(EEC159)
- The Shopping List Report was modified to include Lot Number and
Expiration Date columns.
Additionally, non-expired lot numbers will now be shown on a separate
line on the report and a
line with a blank lot number will be created for items with lots so
users can easily write in
a new lot number. (EEC160)
- When a new lot number for a reagent is received while adding to
inventory via a shopping list,
adding the new lot number required the user to go back to the Items
screen and input it there
first. This has been improved by making a right-click 'Add New Lot'
option available on
Shopping Lists so the new lot can be added from there. (EEC161)
- A Print Preview option has been added to the Print Barcode Labels
window. (EEC162)
- A Set Sequence Order utility has been added onto the Items screen to
allow for arranging items
in groups, changing the group name for all items assigned to it, and
moving items from one
group to another. This feature is also tied to the security permission
of "modify inventory
items" which is only assigned to Administrators by default. (EEC163)
- When the option to print a manual count sheet is used, a new window
will appear which allows
the user to choose from a few different sort options. The option used
will be remembered until
the selection is changed. (EEC164)
- The Item Name field on the Items screen was increased to accommodate
30 characters. (EEC165)
- Inventory (SIS) has been changed from DBISAM 3 to DBISAM 4. (EEC166)
- An error would occur when Inventory (SIS) was closed. This has been
fixed. (EEC170)
- An error would occur in a foreign country using a comma for a
decimal separator in the
calculator of the count sheet. This has been fixed. (EEC181)
- If an Item with Lots defined needs to be ordered, the Shopping List
now contains an entry for
every Lot that has not yet expired. Additionally, all of the Items in
the Shopping list can
have barcodes printed, with multiple barcodes printing for items with
more than one non-expired
lot. (EEC206)
- Inventory (SIS) reports will now all show 'Simple Inventory System'
in the header instead of
'EP Evaluator'. (EEC207)
- Documentation was added to the Help file for Inventory (SIS) on
Reference, Processing Bar Codes
from the Clipboard. (EEC291)
- The font size on the header for the Items screen versus the QOH
screen was different. This has
been fixed. (EEC302)
- The Items screen grid where lot information is entered would
sometimes appear to hide the first
lot entered until the grid was closed and reopened. This has been fixed.
(EEC304)
- Documentation for the Inventory Adjustments Report was added to the
Inventory (SIS) Help file.
(EEC309)
- In some cases, expired lot numbers (which should never have barcodes
printed) were producing
barcode printouts. This has been fixed. (EEC311)
- On the QOH screen, the Create Shopping List and Create Count Sheet
options were separated on
all menus. Additionally, when a new item or lot is defined on the Items
screen, a default
Physical Inventory transaction of 0 and a date of 01 Jan 2000 is created
automatically. The
right-click 'Set Physical Inventory to Zero' option on the QOH screen
will no longer appear
when right-clicking on a Lot (as all lots will have their Physical
Inventory set to zero
regardless). (EEC314)
- A 'Database Check' option has been added to the Utilities menu to
display potential setup
problems on the Items screen that may result in some items missing on
reports. Additionally, an
error count will be displayed at the bottom of the Items screen,
indicating that the DB Checker
should be reviewed for errors. (EEC315)
- Expired lots will now be shown in red on shopping lists and count
sheets. (EEC316)
- If two lots were defined for an item and only one had its Physical
Inventory set from a list,
the second would "disappear" from the lots dropdown on the QOH screen.
This has been fixed.
(EEC325)
9.3.0.448
(03 Dec 2010)
The
following three changes are critical and should not be
overlooked:
- Lin: Reportable Range Pass/Fail is now computed correctly on computers
that use "," as a decimal separator (EEC239)
- EP6: Textual linearity claim is now evaluated correctly on computers
that use "," as a decimal separator (EEC231)
- All StatMods use the same rounding logic to compute statistics. The
rounding rules are now the same for the first report run and all
subsequent reports. Previously, the first report generated could display
slightly different computed results because the rounding rules changed
after the first report was generated (EEC241)
Cost
Per Test
ERI
-
Confidence intervals
are now graphed, even if more than 250 results are present
(EEC218)
-
Reported result
listings are now correct when Analytes like CD3# and CD3% are both
present (EEC218)
Hematology
Method Comparison
INR-MC
Linearity
MIC
-
Focus is no longer
passed to the graphs/charts, preventing them from scrolling by accident
(EEC260)
-
Reports were
reformatted to allow data with many digits to print more legibly
(EEC171)
-
Entering Instruments
into the Parameters screen is now more reliable (EEC93)
Sensitivity
LOB
Simple
Accuracy
Six
Sigma
2IC
Regionalization:
-
ERI/ROC: RRE, current
date is now converted correctly (EEC264)
-
Lin: some computed
values were different on a French computer than on an English computer
(EEC239)
-
Lin: Fixed "No
Results Columns Found" with Paste With Policies, List in French
computer (EEC238)
-
EP6: Fixed "No
Results Columns Found" with Paste With Policies, List in French
computer (EEC238)
-
AMC: Fixed "No
Results Columns Found" with Paste With Policies, List in French
computer (EEC238)
-
EP9: Fixed "No
Results Columns Found" with Paste With Policies, List in French
computer (EEC238)
-
EP6: Textual linearity
claim are now evaluated correctly in French locales (EEC231)
-
Locales which use
";" as the List Separator are now able to acquire data from IM
(EEC129)
-
CPT - Corrected Print
Preview so that using Decimal Separator of "," and Digit
Grouping symbol of " " and List Separator of ";"
does not crash (EEC118)
-
Self Test now works in
Locales which use "," as a Decimal Separator (EEC111)
-
StatMods can now be
opened on computers with Korean regionalization (EEC274)
General
-
Custom logos are no
longer over-written during installation (EEC276)
-
User is now warned if
screen resolution is less than 1024x768 (EEC258)
-
References to EE7, EE8,
etc were changed to EE throughout
-
"Data Innovations,
Inc" changed to "Data Innovations LLC" throughout
(EEC124, EEC228)
-
Minor spelling and
grammatical errors were fixed in the programs and documentation
-
Popup menus clearer for
Exclude and Include of results (EEC119)
-
PRNDLL no longer
crashes if users enter print responses too quickly (INR-MC, Stability,
Interference, 2IC) (EEC190)
-
Paste at the Overview
Screen now detects and warns if Clipboard data is for the wrong StatMod
(EEC215)
-
Copy at the Overview
Screen now contains the correct summary of experiments for the current
StatMod (EEC215)
-
Exported
files that contained "EP Evaluator 8" and now contain "EP
Evaluator" (EEC325)
-
Resources
- Some cells in the PasteWithParmsInSS.XLS
file were reformatted to be numeric with fixed decimal digits (EEC236)
-
Instrument
Manager ODBC - The user is warned
when IM data is wider than can be accepted by EE without truncation
(EEC143)
-
AuditVue
- File, Refresh now operates correctly
(EEC230)
-
File
Manager - If you Restore a Project,
it is now automatically Opened (EEC246)
-
Define
Policies - Errors adding a Cal Kit
with a duplicate name are now handled properly (EEC219)
Reports
-
Minor changes were made
to reports to avoid visual text collisions (Lin, SA, 2IC, INR-MC)
(EEC227)
-
All StatMods use the
same rounding logic to compute statistics. The rounding rules are now
the same for the first report run and all subsequent reports.
Previously, the first report generated could display slightly different
computed results because the rounding rules changed after the first
report was generated (EEC241)
Rapid
Results Entry
-
Corrected the RRE
Wizard so that selecting Instruments now works properly (EEC224)
-
Multiple button
selection popup (Replace, Replace All, Append, Append All, etc)
sometimes resized so as to obscure some buttons (EEC223)
-
Corrected the RRE
Wizard so that correct Cal Kits are now listed after Analyte selection
(EEC222)
-
Corrected RRE so that
Locales which use ";" as the List Separator now can acquire
data (EEC129)
-
IF32DLL.DLL can now
read instrument drivers (CCD files) which are read-only (EEC285)
9.2.0.430
(17 Aug 2010)
-
EEC001 - Enable MIC to
process specimens with some missing resultsEEC013 - Allow paste 2 cols
(X, Y) or 3 cols (SpecID, X, Y) into AMC, QMC, 2IC, POC/Glucose
-
EEC027 - Use
"+/-" instead of "±" for non-English code
pagesEEC038 - Added explanatory screen when user attempts to create new
AON experiment
-
EEC057 - Added
notification to main screen display when a new Release is available for
download
-
EEC059 - Added button
to reveal Print Preview Wide-Screen feature.
-
EEC061 - Added support
for mouse wheel for scrolling in Print Preview.
-
EEC063 - Normalized UI
for all Report Options screens so that focus always starts on OK button
and <enter> moves through all fields
-
EEC064 - <esc>
now exits from RRE, Policy Utilities
-
EEC065 - Added caption
for RRE, Policies, Select Instrument Class icon.
-
EEC067 - Prevent user
from being able to minimize Print Preview, to avoid problems when Print
Preview lost focus.
-
EEC069 - References to
EE8 removed from XLS files in Resources folder
- EEC070 - In RRE->Policies->Linearity
Kits, incomplete kits are now flagged in bold to reduce the chance that
such kits will be left incomplete by accident; also, editing of
concentrations is invoked automatically as each Kit is defined
- EEC071 - GPF crash in CAT now creates more
useful stack traces (added Map)
- EEC074 - Fixed bug where Stability results
sometimes were not correctly sorted by time
- EEC075 - Clarified error message when a
new RRE Instrument Class name already exists.
- EEC076 - Modified API for Activity Log to
minimize future bugs, after an error message was incorrectly flagged and
overlooked by a customer
- EEC079 - User is warned before keyboard
data entered into an RRE grid is discarded.
- EEC080 - Blue back arrow is inhibited
during RRE grid display
- EEC085 - Performance
Standards->Parameters: fixed import of CLIA error limits via icon
- EEC088 - RRE->Connect To Instrument
Manager, Query Wizard, Specimen Options page, for all Modes other than
"Show All", Load Protocol now works
- EEC090 - Removed graph/chart editors on
all charts
- EEC091 - Fixed IM_ODBC failure with
time-related StatMods (CP, LOQ, EP10)
- EEC094 - Enable Paste in Simple Accuracy
Params form for Specimen Targets
- EEC095 - VerifySPClaim checked if
verification params are present during Upgrade
- EEC102 - Simplify ODBC_IM UI for Data
Source selection, remember latest IM data source, user name, password
9.1.0.421 (28 Apr 2010)
- EEC26 - Fixed an problem with long comments not showing on reports.
- EEC29 - Fixed problem in driver with unexpected datastream from Abbott Architect.
- EEC30 - Fixed problem in BC_XF_TOP driver preventing .XLS files from being analyzed.
- EEC33 - Fixed problem where ERI reports for BASO# and BASO% were confused.
- EEC36 - Adjusted widths of data entry grids on various MC forms.
- EEC37 - Fixed problem exiting out of INR CK data entry grid with <esc>.
- EEC40 - Fixed problem where wrong EE logo was displayed.
- EEC44 - Fixed GPF error in the details screen when pressing <esc> twice quickly.
- EEC48 - Fixed GPF error if EP10 low and high bounds were equal.
- EEC49 - Fixed GPF error in Policy Editor problem due to missing file.
- EEC52 - Fixed problem upgrading Professional data with multiple Groups.
- EEC53 - Changed EE9 so that it informs the user if it is already running.
- EEC55 - Fixed problems adding/editing Policy Instruments and
bringing Policy Instruments forward from older Releases.
- EEC56 - Startup Log now available if needed for troubleshooting purposes.
- EEC73 - Fixed cosmetics of panels with New Experiment From Policies.
Note that EEC55 and EEC52 fixed critical bugs. If you use the
HMC module, or are bringing data forward from EE8 or earlier and use
the Professional version of EE9, you should install this release
9.0.0.366 (31 Dec 2009)
- IM Interface: fixed missing dll message. Fixed grayed Send To
button.
- Changed EP9 Report Interpretation Guide to remove statement that
CLSI documents are included with the software.
- LIN, SA: units with powers (like 10^3 uL) now print correctly in
Analytical Claim section of the report.
- CPT: Allow zero in Parameters screen for number of calibrators and
number of controls
- RRE: When sending worksheet to experiments, ask user if s/he wants
to save.
- HMC: Inserted TN/FN/FP/TP labels on Clinical Utility Study report.
- Fixed problem with Web Activation
9.0.0.360 (13 Nov 2009)
- Fixed problem on all modules with specimen list (Lin, SA, etc) where
parameters screen could be closed without defining specimens.
- Fixed problem where CAT would not start on some computers with
Norton Antivirus installed.
- LIN - fixed problem where RR only appeared on the "fixed format"
report if it was verified.
- Fixed a few problems in the Policy Definition precision parameters:
parameters that needed to be set weren't showing up in the list.
- CP and EP10 now support copy/paste and interface of undated files.
- Fixed "Invalid Headers" message when Paste with Policies used on
computers using comma as decimal separator.
- Added a missing configuration file for IM/ODBC interface.
9.0.0.345 (30 Oct 2009)
|